RISK ASSESMENT TOOL
Unified ISO 14971 & FMEA Risk Matrix
1–10 SCALE · 3D (P×D):SMedical Device Risk Estimation, Severity Override Governance & Pre/Post-Mitigation DHF Register
Risk Parameter Inputs
Adjust sliders, dropdowns, or click any cell in the 10×10 matrix
Unified Risk Evaluation
Interactive 10×10 Risk Matrix Explorer
3D RPN View: Showing (P × D) slice at active Severity S = 5
Each cell displays P × D (1–100) and total RPN. Changing S shifts the entire 100-cell plane—automatically turning cells Intolerable when S ≥ 9 or blocking Broadly Acceptable when S ≥ 7.
In ISO 14971, high detectability (D = 1) cannot excuse a catastrophic hazard (S = 10, P = 1 → RPN = 10). Policy overrides ensure low RPN scores never bypass risk controls or Benefit–Risk justification.
ISO 14971 & FMEA Unified Risk Management Worksheet
Pre-mitigation vs. Post-mitigation residual risk evaluation with automatic Policy Override & Benefit-Risk flags
| ID & Component | Hazard → Situation → Harm | Initial (S,P,D) | Initial Zone / RPN | Risk Control Measures | Residual (S,P,D) | Residual Zone / RPN | Governance / BRA | Actions |
|---|
Unified Decision Logic & ISO 14971 Governance Overrides
How numerical FMEA RPN (S×O×D) and 3D Matrix ((P×D):S) combine with mandatory patient-safety overrides
- Hard Override: Any hazard with Severity S = 9 or 10 (Catastrophic), regardless of low P or D.
- Score Trigger: FMEA RPN ≥ 200, or ISO Core S × P ≥ 36, or 3D Matrix (P × D) ≥ 50 when S ≥ 5.
- Action: Mandatory design/process risk control required. If residual risk remains INT, a formal documented Benefit–Risk Analysis (BRA) and Executive/Clinical sign-off are mandatory under ISO 14971.
- Critical Floor Override: Any hazard with Severity S = 7 or 8 (Critical) can never be classified as Broadly Acceptable; minimum zone is ALARP.
- Score Trigger: FMEA RPN 50–199, or ISO Core S × P 15–35.
- Action: Reduce risk As Low As Reasonably Practicable using ISO 14971 hierarchy (1. Inherent Safety → 2. Protective Measures → 3. Information for Safety). Document justification if further reduction is impracticable.
- Eligibility Gate: Only permitted when Severity S ≤ 6 (Moderate or Minor harm).
- Score Trigger: FMEA RPN < 50 AND ISO Core S × P ≤ 14.
- Action: Risk is acceptable without mandatory additional controls; maintain standard quality system monitoring and Post-Market Surveillance (PMS) trending.
Severity of Harm (S: 1–10)
Clinical & patient/user physiological impact
Occurrence / Probability of Harm (O/P: 1–10)
Combined P1 (hazardous situation) × P2 (harm)
Detection / Control Gap (D: 1–10)
Ability of design/process controls to catch prior to harm
Welcome & How to Use: Unified ISO 14971 & FMEA Risk Matrix
Quick-start workflow for Medical Device Risk Management & Design History File (DHF) documentation
Traditional FMEA RPN (S × O × D) can mask catastrophic hazards when occurrence or detection scores are low (e.g., S=10 × O=1 × D=2 = 20). This tool unifies ISO 14971 clinical risk acceptability with FMEA 1–10 scoring using a 3D (P × D) : S matrix and mandatory Severity Policy Overrides.
Use the sliders, rubric dropdowns, or click directly inside the 10×10 Matrix to set Severity (S), Probability of Harm (O/P), and Detection / Control Gap (D). Switch between the 3D RPN Slice (P×D):S and ISO 14971 S×P views anytime.
Every score is automatically classified into Broadly Acceptable (Green), ALARP (Amber), or Intolerable (Red). Hard overrides force S ≥ 9 into Intolerable and S = 7–8 into at least ALARP—preventing low RPN scores from bypassing safety controls.
Click "Log to Risk Register" to record hazards, hazardous situations, and clinical harms. Apply ISO 14971 risk controls (1. Inherent Safety → 2. Protective Measures → 3. Information for Safety), verify residual scores, and track mandatory Benefit–Risk Analysis (BRA) flags.
Export your complete project as an AES-GCM Encrypted & SHA-256 Verified XML file so your team can re-upload, rework, and version-control later. When ready for QMS/DHF audit, generate a Controlled PDF stamped with source details, date, and exact timestamp.
Document Control & Controlled PDF Report
Configure DHF metadata, source attribution, and diagonal security watermark
Save Encrypted XML Project File
AES-256-GCM Encrypted & SHA-256 Integrity-Protected XML Archive